Standard function blocks, Sb068 – Pilz PSS SB HYD, Basic license User Manual

Page 132

background image

6-70

Modular Block System: Hydraulic Presses

Standard Function Blocks

Timing diagram for “double break” mode of ESPE/AOPD

The ESPE/AOPD is set with cycle reset (input parameter

CyRs) via a

pulse at the press TDC.

Input parameters:
RUN = 1:

Static enable for operation of the ESPE/AOPD

STyp = 0: Start-up procedure (cycle mode): first break the protected field

and then reset.

ARSt = 0: No automatic reset of the error “ESPE/AOPD interrupted” after

the protected field is cleared (reset lock).

OFF = 0
GdO = 0

Mode: Double break of ESPE/AOPD (DBrk)

SBrk = 0
DBrk = 1

A function test of the ESPE/AOPD is carried out.
The input parameter

TEST has no effect in “Guard” mode.

It is assigned RLO-0 (M110.00).

Abbreviations:
MaZy

Machine cycle time for cycling the ESPE/AOPD (30 000 ms in
accordance with EN 61 496-1 section A.8.4, 06/98).
This is a global parameter (see also under “Global parameters”
and SB070).