6-1
Modular Block System: Hydraulic Presses
Standard Function Blocks
Guidelines for selecting standard function blocks
Several standard function blocks are available for the following safety
devices:
• E-STOP button
• Safety gate
• Feedback loop and
• Initialisation of the administration data blocks
The following information is designed to help you select the standard
function block that is most appropriate for your application.
Emergency stop monitoring
SB061
NA_1
SB061 is used in applications up to category 4. This standard function
block has no parameter to evaluate the status of I/O-Groups
(SafetyBUS p).
INFORMATION
Do not use SB061 in applications with SafetyBUS p.
SB061 cannot be used to monitor whether contacts switch synchronously
when releasing an E-STOP button that has been operated.
The additional commands for monitoring the SSNR are required
(A DB015, I DW1015). Further information is available in Chapter 5, in the
section entitled “Input parameter SSNR”.
SB063
E-STOP
SB063 is used in applications up to category 4. This standard function
block is suitable for applications with SafetyBUS p. It has an input
parameter to evaluate the status of the I/O-Group (SafetyBUS p), for which
parameters are set on the E-STOP button contacts.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license