beautypg.com

Standard function blocks, Guidelines for selecting standard function blocks, Emergency stop monitoring – Pilz PSS SB HYD, Basic license User Manual

Page 63: Sb061 na_1, Sb063 e-stop

background image

6-1

Modular Block System: Hydraulic Presses

Standard Function Blocks

Guidelines for selecting standard function blocks

Several standard function blocks are available for the following safety
devices:

• E-STOP button

• Safety gate

• Feedback loop and

• Initialisation of the administration data blocks

The following information is designed to help you select the standard
function block that is most appropriate for your application.

Emergency stop monitoring

SB061

NA_1

SB061 is used in applications up to category 4. This standard function
block has no parameter to evaluate the status of I/O-Groups
(SafetyBUS p).

INFORMATION
Do not use SB061 in applications with SafetyBUS p.

SB061 cannot be used to monitor whether contacts switch synchronously
when releasing an E-STOP button that has been operated.
The additional commands for monitoring the SSNR are required
(A DB015, I DW1015). Further information is available in Chapter 5, in the
section entitled “Input parameter SSNR”.

SB063

E-STOP

SB063 is used in applications up to category 4. This standard function
block is suitable for applications with SafetyBUS p. It has an input
parameter to evaluate the status of the I/O-Group (SafetyBUS p), for which
parameters are set on the E-STOP button contacts.