beautypg.com

Pilz PSS SB HYD, Basic license User Manual

Page 39

background image

4-9

Modular Block System: Hydraulic Presses

SB068: Monitoring ESPE/AOPDs with guarding and control function

SB068 is a standard function block which is designed to monitor ESPE/
AOPDs up to category 4, in accordance with EN 954-1, 03/97, with
guarding and control function.

Features:
• Monitors the ESPE/AOPD outputs: feasibility check on the contact

switchover time of the two N/O contacts

• Start-up disabler

• Reset lock

• Test mode

• Cycle mode (control): enabled via single or double break of the ESPE/

AOPD.

• Cycle time monitoring

Operating modes
• AUS (OFF):

Guard function of ESPE/AOPD is deactivated

• Safety (GdO):

ESPE/AOPD as guarding device with reset lock

• 1-Break (SBrK):

Enabled via single break of ESPE/AOPD

• 2-Break (DBrK):

Enabled via double break of ESPE/AOPD

INFORMATION
This block performs safety functions.
When using this block you must comply with the relevant standards and
regulations, in particular:
• EN 61 496-1, 06/98

• Regulations laid down by the manufacturer of your ESPE/AOPD

INFORMATION
Input circuitry: Category 4 ESPE/AOPDs with semiconductor outputs must
be connected to DI 2 inputs (e.g. input module PSS(1) DI 2) in order to
meet the requirements of category 4.