Example D-22 pdt command

Shell> pdt
PDT Information
Last Clear time: PDT has not been cleared
Number of total entries in PDT: 50
Number of used entries in PDT: 0
Number of free entries in PDT: 50
Number of single-bit entries in PDT: 0
Number of multi-bit entries in PDT: 0
Address of first multi-bit error: x0000000000000000

Example D-23 pdt clear command

Shell> pdt clear
Are you sure you want to clear the PDT? [y/N] y
Shell>

Shell> pdt
PDT Information

Last Clear time: 10/21/01 5:00p
Number of total entries in PDT: 50
Number of used entries in PDT: 0
Number of free entries in PDT: 50
Number of single-bit entries in PDT: 0
Number of multi-bit entries in PDT: 0
Address of first multi-bit error: 0x0000000000000000

sysmode

Displays or modifies the system mode.

Syntax

sysmode

Parameters

sets system mode to normal

sets system mode to admin

sets system mode to service

Operation

If specified alone, sysmode displays the system mode. If a mode is specified as a parameter, the
system mode changes immediately. The system mode is retained on successive boots.