Replacing the system battery, Battery location on i/o board, Figure 6-26 – HP INTEGRITY RX3600 User Manual
Page 231
Figure 6-26 Battery Location on I/O Board
1
2
3
4
4
3
1
Core I/O Board Slot
System Battery
TPM
2
I/O VRM
Replacing the System Battery
1.
Insert the replacement battery into the socket on the I/O board assembly.
CAUTION:
You must remove the I/O board assembly to service the system battery. The
removal and replacement of the I/O board assembly occurs through the rear of the rack for
rack-installed servers. Carefully follow the removal and replacement procedures; you must
perform several tasks with the server extended out the front of the rack. See
Replacing the I/O Board Assembly” (page 225)
for complete instructions.
NOTE:
The positive terminal of the battery is designated by the + sign. Install the battery
with the + sign facing up.
2.
Replace the I/O board assembly. See
“Replacing the I/O Board Assembly” (page 228)
3.
Reconnect the power cables and power on the server. See
4.
Reset the server date and time using the EFI date and time commands.
Removing and Replacing the System Battery
231