You can perform the following actions on the View Array screen:
•
To view the next array, press N.
•
To create a new array, press C.
Array
Displays the number of this array.
Identifier
Displays the identifier of this array.
Type
Displays the RAID type.
Scan Order
Displays the scan order of the array.
Size (MB)
Displays the size of the array.
Status
Displays the status of the array.
Bay
Displays the bay in which devices are located.
Device Identifier
Displays the device identifier.
RAID Disk
Specifies the devices (disks) that make up an IM array. If RAID Disk
is Yes, the device is part of an IM array, if No, the device is not part
of an IM array. This field is grayed out under the following conditions:
•
The device does not meet the minimum requirements for use in
an IM array.
•
The device is not large enough to mirror existing data on the
primary drive.
•
This disk has been selected as the hot spare for the IM array.
Hot Spr
Specifies whether a device is the hot spare for an IM array. If hot
spare is Yes, the device is used as a hot spare for the IM array, if No,
the device is not used as a hot spare for the IM array. Only one hot
spare per IM array is permitted. A hot spare is not required in an IM.
A hot spare can be specified at array creation, or any time after
creation, provided the array is made up of 5 disks or fewer. This field
is grayed out under the following conditions:
•
The device does not meet the minimum requirements for use in
an IM array.
•
The array already has a hot spare.
•
The array is made up of the maximum number of devices (6).
•
The device isn't large enough to mirror existing data on the
primary. The hot spare drive must be greater than or equal to
the size of any drive in any IM volume.
Drive Status
xxxx
OK
Disk is online and fully functional.
Missing
Disk is not responding.
Failed
Disk has failed.
Initalizing
Disk is initializing.
CfgOffln
Disk is offline at host's request.
User Fail
Disk is marked failed at host's request.
Offline
Disk is offline for some other reason.
Inactive
Disk has been set inactive.
Not Syncd
Data on disk is not synchronized with the rest of
the array.
Primary
Disk is the primary disk for a 2 disk mirror and is
OK.
Secondary
Disk is the secondary disk for a 2 disk mirror and
is OK.
104