beautypg.com

Basic troubleshooting, Verifying scsi bus configuration – HP STORAGEWORKS E1200-160 User Manual

Page 155

background image

Basic Troubleshooting

155

Network Storage Router e1200-160

Basic Troubleshooting

If possible, simplify the installation by reducing it to the most basic configuration.
Then, add elements one at a time, verifying the operation after each step.

Basic troubleshooting includes verifying the setup and the connections, including:

Verifying SCSI bus configuration

Verifying Fibre Channel port connection

Verifying SCSI devices in Windows NT

Verifying the router configuration

Verifying mapping

Verifying devices

Verifying host configuration

Verifying HBS device driver information

Verifying serial port configuration

Verifying PRLI data

Each of these topics is discussed in the following sections.

Verifying SCSI Bus Configuration

Items to check include:

Termination — Problems with termination can cause intermittent or hard
failures. A SCSI bus must be terminated on both ends. Termination problems
are common when both narrow and wide devices are on the same bus.

Bus Type — On an LVD SCSI bus, SE and LVD devices can be connected to
the same bus. However, if one SE device is detected during power up,
communication to all devices will convert to SE mode.

Device ID — Each device on a SCSI bus must have a unique ID. Verify
configured IDs are not in use by other devices on the same SCSI bus.

Cabling — Check SCSI cables to verify they are functional. SCSI rules for
total length, distance between devices, and stub length must be followed.
Connections should also be checked and reseated if necessary.

SCSI Devices — Verify that the SCSI devices on a particular SCSI bus can
be seen in the Configuration Menu of the router. If the router cannot see the
devices, verify SCSI configuration, cabling, and termination.