Serial/Telnet User Interface
141
Network Storage Router e1200-160
Note:
Initially, the factory default router IP address is 1.1.1.1. To view the current IP
address, navigate to the Ethernet Configuration Menu and view the screen display.
See the “Configuration Menu” section for information on viewing and changing the
router IP address.
4. Specify the directory location on the computer or network where the FTP
program will store the trace file.
5. Enter the user name and password.
The factory default user name is
root
and the default password is
password
.
6. Specify Bin mode:
bin
7. Enter the appropriate command to copy the current or previous trace buffer:
■
To copy the current trace buffer:
get curtrace.txt
■
The file will transfer from the router.
■
To copy the previous trace buffer:
get prvtrace.txt
■
The file will transfer from the router.