Operation Manual

82

6.7 System Information

You can view the information, including version, log and online user, and back up or clear log.

6.7.1 Version

Select

>

System Info

>

Version

to view device information such as hardware, system version,

and web version.

6.7.2 Online User

Select

>

System Info

>

Online User

to view all the online users logging in to web.

6.8 Setting Log

6.8.1 Log

You can view and back up logs.
Step 1

Select

>

Log

>

Log

.

Step 2

Configure

Start Time

and

End Time

, and then select the log type.

The start time should be later than January 1, 2000, and the end time should be earlier
than December 31, 2037.
The log type includes All, System, Setting, Data, Event, Record, Account, and Safety.

System

: Includes program start, abnormal close, close, program reboot, device

closedown, device reboot, system reboot, and system upgrade.

Setting

: Includes saving configuration and deleting configuration file.

Data

: Includes configuring disk type, clearing data, hot swap, FTP state, and record

mode.

Event

(records events such as video detection, smart plan, alarm and abnormality):

includes event start and event end.

Record

: Includes file access, file access error, and file search.

Account

: Includes login, logout, adding user, deleting user, editing user, adding group,

deleting group, and editing group.

Security

: Includes password resetting and IP filter.

Step 3

Click

Search

.

Click

or click a certain log, and then you can view the detailed information in

Details

area.

Click

Backup

, and then you can back up all found logs to local PC.