7 system information, 1 version, 2 online user – Dahua Technology DH-IPC-EBW81242N-AS-S2 12MP Outdoor Network Panoramic Fisheye Camera with Night Vision User Manual
Page 93: 8 setting log, 1 log

Operation Manual
82
6.7 System Information
You can view the information, including version, log and online user, and back up or clear log.
6.7.1 Version
Select
>
System Info
>
Version
to view device information such as hardware, system version,
and web version.
6.7.2 Online User
Select
>
System Info
>
Online User
to view all the online users logging in to web.
6.8 Setting Log
6.8.1 Log
You can view and back up logs.
Step 1
Select
>
Log
>
Log
.
Step 2
Configure
Start Time
and
End Time
, and then select the log type.
The start time should be later than January 1, 2000, and the end time should be earlier
than December 31, 2037.
The log type includes All, System, Setting, Data, Event, Record, Account, and Safety.
●
System
: Includes program start, abnormal close, close, program reboot, device
closedown, device reboot, system reboot, and system upgrade.
●
Setting
: Includes saving configuration and deleting configuration file.
●
Data
: Includes configuring disk type, clearing data, hot swap, FTP state, and record
mode.
●
Event
(records events such as video detection, smart plan, alarm and abnormality):
includes event start and event end.
●
Record
: Includes file access, file access error, and file search.
●
Account
: Includes login, logout, adding user, deleting user, editing user, adding group,
deleting group, and editing group.
●
Security
: Includes password resetting and IP filter.
Step 3
Click
Search
.
●
Click
or click a certain log, and then you can view the detailed information in
Details
area.
●
Click
Backup
, and then you can back up all found logs to local PC.