25

Table 6-9 Description of fisheye parameters

Parameter

Description

installation Mode

You can select

Ceiling

,

Wall

, or

Ground

.

Record Mode

1O: The original image before correction.

1P: 360° rectangular panoramic image.

2P: When the installation mode is

Ceiling

or

Ground

, you can set

this mode. Two associated 180° rectangular image screens; at any
time, the two screens form a 360° panoramic image.

1R: Original image screen + independent sub-screen. You can

zoom or drag the image in all the screens.

2R: Original image screen + two independent sub-screens. You

can zoom or drag the image in all the screens.

4R: Original image screen + four independent sub-screens. You

can zoom or drag the image in all the screens.

1O + 3R: Original image screen + three independent sub-screens.

You can zoom or drag the image in original image screen, and
move the image (upper and lower) in sub-screens to adjust the

vertical view.

Step 3

Click

Apply

.

6.2.2 Setting Encode Parameters

This section introduces video parameters, such as video, snapshot, overlay, ROI (region of interest),
and path.

Click

Default

, and the device is restored to default configuration. Click

Refresh

to view the latest

configuration.

6.2.2.1 Encode

Configure video stream parameters, such as compression, resolution, frame rate, bit rate type, bit
rate, I frame interval, SVC, and watermark.
Step 1

Select

>

Camera

>

Encode

>

Encode

.