Procedure

1. Select

AI

>

Smart Plan

.

2. Click

next to

IVS

to enable IVS of the corresponding channel, and then click

Next

.

3. Click the

Global Config

tab.

Figure 8-21 Global configuration of IVS

4. Set calibration area and ruler.

a. Click

and draw a calibration area in the image, and right-click to finish the drawing.

b. Click the ruler icon to draw one horizontal ruler and three vertical rulers in the calibration

area.

indicates vertical ruler, and

indicates horizontal ruler

Select an added ruler, and click

to delete the ruler.

5. Set the sensitivity.

Adjust the filter sensitivity. With higher value, it is easier to trigger an alarm when low-contrast
object and small object are captured, and the false detection rate is higher.

6. Click

Apply

.

Result

1. Select the verification type, and then click

Calibration Verification

.

To verify vertical ruler and horizontal ruler, respectively select

Height Verification

and

Width

Verification

.

2. Draw a straight line in the image to verify whether the rulers are correctly set.

In case of big difference between the estimated value and the actual one, fine-tune or reset
parameters until the error requirement is met.

8.4.2 Rule Configuration

Set rules for IVS, including cross fence detection, tripwire, intrusion, abandoned object, moving
object, fast moving, parking detection, crowd gathering, and loitering detection.

Select

AI

>

Smart Plan

, and enable

IVS

.

Select

AI

>

Smart Plan

>

Global Config

to finish global configuration.