beautypg.com

2 record linkage, Prerequisites, Setting record linkage – Dahua Technology DH-IPC-EBW81242N-AS-S2 12MP Outdoor Network Panoramic Fisheye Camera with Night Vision User Manual

Page 69

background image

Operation Manual

58

Figure 6-50 Schedule

Step 2

Press and drag the left mouse button on the timeline to set arming periods. Alarms will be
triggered in the period in green on the timeline.

Click

Copy

next to a day, and select the days that you want to copy to in the prompt

interface, you can copy the configuration to the selected days. Select the

Select All

check box to select all days to copy the configuration.

You can set 6 periods per day.

Step 3

Click

Apply

.

Step 4

(Optional) Click

Time Plan Table

to add a new time plan table.

You can:

Double-click the table name to edit it.

Click

to delete the tale as needed.

6.4.1.2.2 Record Linkage

The system can link record channel when an alarm event occurs. After alarm, the system stops
recording after an extended period according to the

Post-Record

setting.

Prerequisites

After the corresponding alarm type (

Normal

,

Motion

, or

Alarm

) is enabled, the record channel

links recording. For details, see "10.3 Setting Record Plan".

Enable auto record mode, the record linkage will take effect. For details, see "10.2 Setting Record

Control".

Setting Record Linkage

On the

Alarm

interface, click

to enable record linkage, select the channel as needed, and set

Post-Record

to set alarm linkage and record delay.

After

Post-Record

is configured, alarm recording continues for an extended period after the alarm

ends.