beautypg.com

Appendix 2: gpi out, Ppendix – Datavideo SE-1200MU 6-Input Switcher and RMC-260 Controller Bundle User Manual

Page 82

background image


82


Appendix 2: GPI Out

The SE-1200 MU can control external recorder/playback devices via simple contact closure GPI switch.

The GPI interface is a 3.5mm Jack Socket which is situated on the rear panel of the SE-1200 MU.
Contact closure between the Outer and Inner contacts on the jack plug will trigger a user selected event.
Power is supplied by the SE-1200 MU and is less than 5V DC.

This GPI socket can also be used as a socket to trigger record or playback events with other equipment
such as the Datavideo HDR-70 recorder.

SAFETY FIRST

The cabling required needs to be designed specifically to connect the SE-1200 MU to the

chosen record or playback device as they are not all the same. The cabling required can be made by
yourself or a competent technician. Please speak with your Dealer or local Datavideo office to get further
help and advice.

Outputs Menu

This allows the user to perform GPI configuration.

Windows PC Users

MAC Users


After turning

On

the GPI

Enable

, select the GPI

Mode

, which is either set as

Level

or

Pulse

. The GPI signal

Width

can also be configured by setting a value (1~9).

The GPI out can then be assigned to one of the inputs 1~4 under

Source

. When the selected

channel/source is taken to the Program output the GPI signal is triggered. A GPI

Delay

can be set between

0 and 99.

This feature could be used to trigger playback from units such as the Datavideo

NVP-20

or

HRS-30

or

HDR-

60/70

.