3 exporting and importing stills, Ssigning a, Aved – Datavideo SE-1200MU 6-Input Switcher and RMC-260 Controller Bundle User Manual

Page 68: Till, Mage to an, Nput, Hannel, Xporting and, Mporting, Tills

background image


68


9.2

Assigning a Saved Still Image to an Input Channel

In the previous two

pages

we covered how to freeze a live input for capturing into the Stills matrix on the

SE-1200 MU. Now we want to use that previously saved still image in our next production.

1.

Using the

Preset source row

select the input channel to be used for displaying the saved still image.

This will also place that input channel onto the Preview window in the SE-1200 MU Multi view. Do not
worry if at this stage it is still currently showing live or no images.

2.

Next click the

Stills

button on the

MENU SELECT

panel.

Windows PC Users

MAC Users

3.

Click

Still Load

in the yellow options area on the left.

4.

Change the

Still Buf option

in the lower row of

options

to match the desired bus channel

that you wish

to use to display the still image. In our example we have chosen

Input 1

.

5. Now select the required saved still within the stills matrix.

Use the up and down triangle buttons on

the right to scroll through the matrix if necessary. Empty memory points will appear as blue thumbnail
boxes without a number. Alternatively enter the

Still value

and then click

Load Still

.

6.

The input channel will now display only the selected still image. To change the still to another repeat

step 5. To return the input channel to live video again see beginning of this chapter.

9.3

Exporting and Importing Stills

A previously saved SE-1200 MU still image can be exported from the Switcher to the User’s computer. This
Still file can then be imported into another SE-1200 MU switcher or used in other ways such as event
marketing or disc authoring. This can be useful if creatively branding productions the same way.