43 erps <1-64> mep – PLANET MGSW-28240F User Manual
Page 73

Command Guide of MGSW-28240F
<1-64> ERPS group number
interconnect Major ring is interconnected
Default:
0
Usage Guide:
To create a profile and configure the Major ERPS interface port 0, port 1.
Example:
To create a profile 1 and configure the Major ERPS interface port 0(GigabitEthernet 1/1), port 1(GigabitEthernet 1/2)
without interconnected mode
Switch# configure terminal
Switch (config)# erps 1 major port0 interface GigabitEthernet 1/1 port1 interface
GigabitEthernet 1/2
4.2.43 erps <1-64> mep
Command:
erps <1-64> mep port0 sf
aps
<1-64> ERPS group number
Default:
0
Usage Guide:
To configure ERPS Instance Data for specific ERPS profile.
Example:
To configure ERPS Instance Data(Port0: SF MEP = 2, APS MEP = 1. Port1: SF MEP = 4, APS MEP = 3) for specific
ERPS profile(1).
Switch# configure terminal
Switch (config)# erps 1 mep port0 sf 2 aps 1 port1 sf 4 aps 3
-73-