190 rmon event – PLANET MGSW-28240F User Manual
Page 288
![background image](https://www.manualsdir.com/files/865112/content/doc288.png)
Command Guide of MGSW-28240F
ifOutNUcastPkts The number of broad-cast and multi-cast packets that request to transmit
ifOutOctets The number of octets transmitted out of the interface, including framing characters
absolute Test each sample directly
delta Test delta between samples
rising-threshold Configure the rising threshold
falling-threshold Configure the falling threshold
both Trigger alarm when the first value is larger than the rising threshold or less than the falling threshold (default)
falling Trigger alarm when the first value is less than the falling threshold
rising Trigger alarm when the first value is larger than the rising threshold
Default:
None
Usage Guide:
To configure the Alarm of RMON
Example:
To configure the Alarm (below table) of RMON
Switch# configure terminal
Switch (config)# rmon alarm 1 .1.3.6.1.2.1.2.2.1.10.15 50 absolute rising-threshold
1000 1 falling-threshold 520 1 falling
4.2.190 rmon event
Command:
rmon event
rmon Remote Monitoring
event Configure an RMON event
description Specify a description of the event
-288-