Command Guide of MGSW-28240F
lb Loop Back
count The number of LBM PDU to send in one loop test. The value 0 indicate infinite transmission (test behavior). This
is HW based LBM/LBR and Requires VOE.
size The number of bytes in the LBM PDU Data Pattern TLV
PDU - including CRC (four bytes). Example when 'Size' = 64 => Un-tagged frame size = DMAC(6) + SMAC(6) +
TYPE(2) + LBM PDU LENGTH(46) + CRC(4) = 64
interval The number of bytes in the LBM PDU Data Pattern TLV
'count' == 0 this is in 1us and max is 10.000.
dei Drop Eligible Indicator in case of tagged OAM.
multi OAM PDU is transmitted with multicast MAC.
uni OAM PDU is transmitted with unicast MAC. The MAC is taken from
peer MEP MAC database.
mac Loop Back unicast MAC to be used in case of LB against MIP.
mep-id Peer MEP-ID for unicast LB. The MAC is taken from peer MEP MAC database.
Default:
None
Usage Guide:
To configure Loop Back of MEP.
Example:
To configure Loop Back of MEP 2 as below table
Switch# configure terminal
Switch (config)# mep 2 lb 1 dei count 10 size 64 interval 100