beautypg.com

3 fault tolerance, Fault tolerance, Megaraid 320 fault tolerance features – Avago Technologies MegaRAID SCSI 320-0 (520-0 CH) User Manual

Page 56

background image

3-16

MegaRAID 320 Storage Adapter Characteristics

Copyright © 2003-2008 by LSI Corporation. All rights reserved.

3.3.3

Fault Tolerance

Table 3.9

shows the MegaRAID 320 fault tolerance features.

Table 3.9

MegaRAID 320 Fault Tolerance Features

Specification

MegaRAID
320-1

MegaRAID
320-2

MegaRAID
320-2E

MegaRAID
320-2X

MegaRAID
320-4X

Support for
SMART

1

Yes

Yes

Yes

Yes

Yes

Optional Battery
Backup for
Cache Memory

3.6 V/600mAH
battery pack.
Up to 48 hours
of data
retention for
64 MB.

3.6 V/600mAH
battery pack.
Up to 24 hours
of data
retention for
128 MB.

4.8 V/880mAH
battery pack.
Up to 72 hours
of data
retention for
128 MB.

3.6 V/650mAH
battery pack.
Up to 24 hours
of data
retention for
256 MB.

3.6 V/650mAH
battery pack.
Up to 24 hours
of data
retention for
256 MB.

Drive Failure
Detection

Automatic

Automatic

Automatic

Automatic

Automatic

Drive Rebuild
Using Hot
Spares

Automatic

Automatic

Automatic

Automatic

Automatic

Parity
Generation and
Checking

Yes

Yes

Yes

Yes

Yes

1.

The Self Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all
predictable disk drive failures. In addition, SMART monitors the internal performance of all motors,
heads, and drive electronics.