Operating the Solar-Log 500 and 1000 via the Display

5 Operating the Solar-Log 500 and 1000 via

the Display

5�1

Display Solar-Log 500

In additional to the web interface described above, the Solar-Log 500 also has a two-line text display on

which the current power data can be displayed.

The following values are displayed at regular intervals.

Name

Unit

Meaning

Feed-in power Pac

W

Current amount of feed-in power P
on the AC side

Generator Power Pdc

W

Current amount of feed-in power
P on the DC side (Solargenerator)
If only one multi-string inverter
has been selected, the individual
strings are displayed separately.

YDay

kWh

Daily yield

Yspec

Wh/Wp

Specific power "performance in
kW/kWp." After that, all of the val-
ues will be comparable in regard
to their specific output. Diminish-
ing module performance can also
be recognized.

5�2 Display Solar-Log 1000

The Solar-Log 1000 comes with a touchscreen that allows for quick and easy access to performance data,

diagnostic information and inverter logs. It also allows a data transfer to be performed via USB.

Note:

Never use a sharp, pointed object on the touch screen!

This will damage the screen's delicate surface.