Operating via a web browser within your own network
Selecting "OK" redirects you to the page of the Solar-Log™ for firmware updates. Selecting "Cancel" closes
the window.
Access control
Access protection for different parts of the Solar-Log™ can be configured in this menu. The following
sections can be restricted with a pin code or password.
•
Access protection for the display
•
Access protection for the browser menu
•
Displaying advanced configuration
Access protection for the display (only Solar-Log 1000, 1200 and 2000)
A pin code can be activated to restrict access to the Solar-Log™'s display. The pin code may contain a
maximum of 8 numerical digits.
Access at the display can be restricted for the entire display or just the settings section.
Procedure:
•
Enter the
pin code
•
Enter the
pin code
again
•
Select
restricted
Sections
by checking them.
•
SAVE
settings
Access protection for the browser menu
In this section, the following parts of the Solar-Log™'s browser menu can be restricted with a password:
•
User
General access to the
Browser menu
•
Installer
Access to the
Configuration
menu
•
Feed-in management
Access to the
Configuration | Special Functions | Feed-in Management
menu
The default password for access to the Feed-in Management menu is PM. Access for users and installers is
not restricted.
Note
We advise installers to discuss with their customers the scope of the settings in the area
of feed-in management, to block the configuration menu using a password and to assign
an individual password.
Procedure
•
Activate the
password restriction
for the desired menus
•
Enter
a secure password for each of the menus
•
Enter the password again
•
SAVE
settings