77

Notifications

The output measured from the inverters is contrasted with the generator capacity that is listed in the sys-

tem.

A notification is sent (by email) when the deviation exceeds the amount configured (for example 10%) over

a set time period (for example 30 minutes).

Note

!

For performance monitoring configurations, see the chapter "

Configuring Notifi-

cation

" in the

Installation Manual

.

3�2�1 Performance Monitoring Notification

Example Notification:

Module Field 1 - Inverter 1 'Inverter 1 House'

IRV = 4916W ( Inverter 2, Inverter 2 House' ), IAV = 3950W, deviation = 19.65 %

The notification contains the following information:

Module field:

The module field which was affected or at least the module field in which a deviation was detected.

Deviating inverter:

Inverter 1

IRV:

The reference value that is used to contrast inverters. It comes from the most effective operating inverter,

the value is in W.

IAV:

The amount of output from inverter with a deviation.

Dev:

The amount of deviation as a percentage of the reference value.