Total plant, Smart appliance, Profiles – Solare Datensysteme Solar-Log User Manual
Page 66

66
Operating via a web browser within your own network
Total Plant
Production [W]
The production from the entire plant in watts.
Consumption [W]
The entire consumption in watts.
Remaining surplus [W]
Surplus that is still fed into the grid.
Smart Home Consumption [W]
This value is comprised of the nominal power of all of the currently active profiles and the current output
from the controlled smart appliances.
Theoretical surplus [W]
Theoretical surplus is the amount that would be fed into the grid if no Smart Home logic was operating
(including smart appliances).
This is based on the following calculation:
Surplus (Remaining surplus) + the nominal power of all of the
currently active profiles + the current power consumption of the smart appliances.
Smart appliance
(is displayed when an smart appliance is connected)
Available surplus [W]
The available surplus consists of the remaining surplus (production minus consumption) and Smart Home
consumption. This surplus is transferred to the smart appliance as available surplus.
Consumption [W]
This is the power consumption from EGO Smart Heater.
Profiles
(are only displayed when profiles have been configured)
Profile 1 - Surplus management
Available surplus [W]
The available surplus corresponds to the value transferred to the first profile after amount of power con-
sumed by the smart appliance is deducted (in the example: Profile 1 Surplus management).
Consumption [W]
In this example, this is the power consumption from the device connected in Profile 1.
Profile 2 - Heatrod 3-stage digital
Available surplus [W]
The available surplus corresponds to the value transferred to the second profile after amount of power
consumed by first profile is deducted (in the example: Profile 2 - Heatrod 3-stage digital).
Consumption [W]
In this example, this is the power consumption from the heatrod connected in Profile 2.
The symbols displayed to the right of the current values indicate which switches or relays are active or
inactive. In addition, the each corresponding section can be displayed or hidden on top-left above the
symbol.