Solare Datensysteme Solar-Log User Manual

Page 54

background image

54

Operating via a web browser within your own network

Explanation of the Symbols in the Feed-in power (% DC) column:

The feed-in power value is in the target power range with a tolerance of -2% to +1%.

The feed-in power value is below the target value allowed. Generally, this means that the out-

put allowed at the grid connection point is not being achieved due to low irradiation or high

self-consumption.

This means that the value is above the target value allowed.

If the red triangle is only displayed at a bus and entire plant has a green symbol, this means

that only this bus is over the target value allowed. However, the plant totals do not go over the

target value because of self-consumption.

Explanation of the Values in the Reactive Power Reduction Section

The following values are displayed in the Reactive Power Reduction section:

Reactive Power determined by:

The currently active control source is indicated in this field.

Displayed Text

Explanation

Text

PMC_NONE

No control source.

PMC_DIAG

Controlled by the diagnostic mode.

PMC_MODBUS_2

Controlled by the ModBus PM V2 (new ModBusPM).

PMC_MODBUS_1

Controlled by the ModBus PM V1 (old ModBusPM).

PMC_PROFILE

Controlled by the PM Profile.

PMC_INTERN

Controlled by the internal configuration.

PMC_DM_MODBUS

Controlled by direct seller via ModBusDM.

PMC_DM_RCR

Controlled by direct seller via ripple control receiver