Secondary Type of Reactive Power Control:
If "PMF_RP_ADJUSTABLE" is entered as the "Type of Reactive Power Reduction,"
the variable assignment from the selected type of reactive power control is indicated in this field.
For example, a PM profile defines that the type of reactive power control is determined by the Adam Box.
That means:
The profile is responsible for the control. It is set up in the profile that the control can be selected via the
Adam Box.
The type of control selected is displayed under "Secondary Type of Reactive Power Control."
The possible values are identical to those for "Type of Reactive Power Control."
Secondary value specification from:
When a secondary control is used, the source of the control value is indicated in this field. The possible
values are identical to those for "Value specification from."
Cos(Phi):
The value defined in the Configuration | Special Functions | Feed-In Management | Reactive Power Control
is displayed in this field.
Reactive power (Var):
The value defined in the Configuration | Special Functions | Feed-In Management | Reactive Power Control
is displayed in this field.