Faults (Solar-Log 200, 500 and 1000)

Faults

LED 1

LED 2

LED E

LED P

Meaning and possible remedy

quickly

quickly

off

For 5 min. during initialization:
Error!

»

Pull out power plug and plug
in again.

lit

slow

slow

Failed to synchronize the time via
the Internet.

»

Set the time manually.

»

Check Internet connection.

off

slow

slow

Configuration invalid or not read-
able:

»

Check interface.

»

Check cable.

»

Restarting.

lit

Only with Fronius inverters:
No data communication!

»

Wait for inverter feed-in

»

Check the wiring.

quickly

Plant has reported a fault.

slow

If the P LED is blinking, this indi-
cates that the inverter is being
controlled (power reduction) by
the feed-in power management.

12�2 Troubleshooting faults oneself

You can remedy faults yourself by restarting the device. A restart is necessary if the device no longer re-

acts to entries in the web browser.

All settings made on the device remain in place, as well as all data collected during run-time.

To restart the device, use the reset button at the top of the device.


Fig.: Reset button on the top of the device

Opening the cover

If the cover is on, you must first remove the cover from the device. If needed, you can also find the So-

lar-Log™'s serial number here.