beautypg.com

2 fault – KACO blueplanet 750 - 1000 kVA User Manual

Page 64

background image

Page 64

KACO blueplanet 1000/875/750 TL3 M1 IS OD DEX0

Faults and Warnings

6.3.2 Fault

Code Message

Warning Description

Possible problem and Solution(s)

1

PV Over Voltage

PV voltage exceeds the param-
eter [DC over voltage Level]

Possible problem
• The voltage of the solar generator is too
high
Solution(s)
• Check the input voltage
• Check module wiring and system

2

PV Over Current

PV current exceeds the parame-
ter [DC over current Level]

Possible problem
• The current of the solar generator is too
high
• PV system wiring short
Solution(s)
• Check the input current
• Check module wiring and system

4

CB10 (PV CB) Trip

PV side circuit breaker (DS10)
tripped

Possible problem
• DS10 disconnect switch is open
• Auxiliary switch is inoperable, DS10
contactor failed closed
Solution(s)
• Check the wiring connection
• Change the DS10, replace DS10 contactor

5

PV Polarity Failure

Polarity (+, -) of PV side is
reversed

Possible problem
• Polarity of PV side is reversed
Solution(s)
• Check the wiring connection and
change if necessary

6

Ground Fault

PV side ground fault

Possible problem
• The GFDI fuse in inverter is opened
causing PV side grounding or short-
circuit fault (DC side Grounding Type)
• The unbalance of measured PV voltage
in inverter causing PV side grounding or
short-circuit fault (DC side Isolation Type)
Solution(s)
• Check the solar generator for a grounding
or short-circuit fault and Replace the
GFDI Fuse (DC side Grounding Type)
• Check the solar generator for a grounding
or short-circuit fault (DC side Isolation
Type)

Table 8: Fault