Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 56

background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 55 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

55

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

175FD

95741

30205

Alm:Ovrtrq Det 2

OL4 – Overtorque detect 2 alarm.
Output current exceeded Overtorque
Detection Level 2 set in inverter
parameter L6-05. For V/F control,
parameter L6-05 is considered to be
Output Current.

Yes

Yes

Yes

Minor

Minor

The input labeled ‘Minor’ is set only
if L6-01 = 1 or 2. Reduce load,
increase acceleration time, or
increase inverter parameter setting
L6-02.Reduce load, increase
acceleration time, or increase inverter
parameter setting L6-05.

175FE

95742

30206

Alm:External Flt

Both FWD and RUN commands are
simultaneously input for 500ms or
longer.

Yes

Yes

Yes

Minor

Minor

Check input wiring to ensure that
FWD and REV are mutually
exclusive.

175FF

95743

30207

Alm: BB Circuit

Base Block activated by external
contact into terminal programmed
for base block.

Yes

Yes

Yes

Minor

Minor

Note: Assuming one of the input
terminals is programmed for external
BB and the BB is being asserted by
an external contact, an overspeed or
max overheat of drive will cause
inverter BB of signals to the power
devices. Recycle SmartTrac AC1
power. If problem persists, replace
inverter card.

17600

95744

30208

Alm: Ext Fault 3

EF3 – External fault signal at
terminal 3 of the inverter card. This
can be programmed to be N.O. or
N.C. contact.

Yes

Yes

Yes

Minor

Minor

Fault has occurred in circuits outside
the Smart Trac AC1 inverter card.
Troubleshoot and correct. Alarm
declared only if H1-01 is in the
range of 2Ch to 2Fh.