Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 17

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 16 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
16
Displayed Fault No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
Fault Legend
Description
27
39
Bad Bit
Number
Requested bit number is
unavailable.
No
Yes
Yes
Minor
Minor
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.
28
40
Bad Data Size
Mismatch found when
performing computation on 2
differing data types.
No
Yes
Yes
Minor
Minor
Check application program for data type
mismatches.
29
41
Bit Out of
Range
Logical bit does not fit within
bounds of data type. For
example, an attempted was made
to OR bit 0x0800 with a byte.
No
Yes
Yes
Minor
Minor
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.
2A
42
Bad Function
Ptr
Pointer to a Function Block call
is invalid. ‘C’ FB cannot be
processed.
No
Yes
Yes
Minor
Minor
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.
2B
43
Bad Lower
Bound
Index into an internal array has
exceeded the lower bounds.
No
Yes
Yes
Minor
Minor
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.