Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 36

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 35 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
35
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault #
Fault Legend
Description
14EF1
85745
20209
LAN Rem Logic
In
Logic Input Request
Fault – This message
is sent from the remote
I/O node to the Smart
Trac AC1 drive when
the remote I/O node
cannot provide a
logical input for
reasons other than
LAN failure.
No
Yes
Yes
Minor
Minor
A typical reason for this condition might be
there is no logic I/O channel located at the
given channel.
14EF2
85746
20210
LAN Rem Num
Out
Numeric Output
Allocation Fault – The
requested numeric
output allocation could
not take place because
of an allocation
conflict with another
device or the absence
of the device(s) being
requested.
No
Yes
Yes
Minor
Minor
Check for duplicate LAN node, channel and
subchannel in drive programs. Possible
incorrect setting of node channel or
subchannel at remote device.