Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
51
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault
No
.
Fault Legend
Description
small test program to see if fault
persists.
17572
95602
30066
CPF21 Fault
Option CPU down. Smart Trac AC1
self-diagnostic error.
Yes
Yes
Yes
Minor
Major
Smart Trac AC1 CPU card may be
programmed incorrectly. Check for
valid Boot, Monitor, and Kernel
firmware.
17573
95603
30067
CPF22 Fault
Option Type Err. Smart Trac AC1
Model code error.
Yes
Yes
Yes
Minor
Major
Smart Trac AC1 CPU card may be
programmed incorrectly. Check for
valid Boot, Monitor, and Kernel
firmware. Check Inverter Type in
Boot menu: for most cases, value
should be set for 2 ms Torq Update.
17574
95604
30068
CPF23 Fault
Option DPRAM Err. Smart Trac
AC1 DPRAM error. Dual Port
RAM handshake between Smart
Trac AC1 CPU card and inverter
card has been lost.
Yes
Yes
Yes
Minor
Major
Check physical connection of both
Smart Trac AC1 CPU card and PG
card. Application program may be
bad or extremely overburdened.
17575
95605
30069
Not used
17576
95606
30070
Not used
17577
95607
30071
Not used
17578
95608
30072
Not used
17579
95609
30073
Not used
1757A
95610
30074
Not used
1757B
95611
30075
Not used
1757C
95612
30076
Not used
1757D
95613
30077
Not used