Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 13

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 12 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
12
Displayed Fault No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
Fault Legend
Description
15
21
Operand2
Invalid
2
nd
operand code within program
is unrecognized. Valid Opcodes
are add, subtract, AND, OR, etc.
Yes
Yes
Yes
Major
Major
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. Replace the SmartTrac
CPU card.
16
22
Operand1
Invalid
1
st
operand code within program
is unrecognized. Valid Opcodes
are add, subtract, AND, OR, etc.
Yes
Yes
Yes
Major
Major
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.
17
23
Invalid Jump
Calculated offset appears outside
the bounds of the program.
Branch cannot be completed.
Yes
Yes
Yes
Major
Major
Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.
18
24
Invalid
Address
Address does not appear within
NVRAM, DRAM, nor Task
table.
Yes
Yes
Yes
Major
Major
Check memory allocation for this node in Smart
Trac Workstation software. In Configure dialog
box, make sure the following is true: Base
Address = 0x300000, Base Memory Size =
0x100000, Retentive Address = 0xDC000, and
Retentive Size = 0x3F00. The Smart Trac main
CPU card may be faulty. If available, download
a small test program to see if fault persists