Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 51

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 50 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
50
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault
No
.
Fault Legend
Description
17562
95586
30050
Not used
17563
95587
30051
CPF02 Fault
BB Circuit Failure. Baseblock
circuit fault.
Yes
Yes
Yes
Minor
Major
Major faults like overspeed or max
overheat of drive will cause inverter
baseblock of signals to power
devices. Recycle Smart Trac AC1
power. If problem persists, replace
inverter card.
17564
95588
30052
CPF03 Fault
EEPROM Error. EEPROM fault.
Yes
Yes
Yes
Minor
Major
Attempt to initialize Smart Trac AC1
inverter card. Replace inverter card if
failure persists
17565
95589
30053
CPF04 Fault
Internal A/D Err. Internal A/D fault.
Yes
Yes
Yes
Minor
Major
Replace inverter card.
17566
95590
30054
CPF05 Fault
External A/D Err. External A/D
fault.
Yes
Yes
Yes
Minor
Major
Replace inverter card.
17567
95591
30055
CPF06 Fault
Option Error. Option card
connection failure.
Yes
Yes
Yes
Minor
Major
Check physical connection of both
Smart Trac AC1 CPU card and PG
card to inverter card.
17568
95592
30056
Not used
17569
95593
30057
Not used
1756A
95594
30058
Not used
1756B
95595
30059
Not used
1756C
95596
30060
Not used
1756D
95597
30061
Not used
1756E
95598
30062
Not used
1756F
95599
30063
Not used
17570
95600
30064
Not used
17571
95601
30065
CPF20 Fault
Option A/D fault in analog Speed
Reference card.
Yes
Yes
Yes
Minor
Major
The Smart Trac main CPU card may
be faulty. If available, download a