beautypg.com

Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 24

background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 23 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

23

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

12AFE

76542

11006

PG Card ID
Error

The PG card can’t be found. This is
due to the software not seeing the
correct identification code on the PG
card.

Yes

Yes

Yes

Minor

Major

The correct PG card must be installed for
the Smart Trac AC1 function blocks
used.

12AFF

76543

11007

PG A/D
Retries

The PG_ANALOG_IN function
block senses that the PG card has not
done an analog to digital conversion
in the allotted time after the number
of attempts set by the TriesB4Fault
input to the PG_ANALOG_IN
block.

No

Yes

Yes

Minor

Minor

Try increasing the number of attempts
for conversion, TriesB4Fault, to a higher
value. Possibility the PG card is
defective.

12B00

76544

11008

I/O Memory
Alloc

Dynamic RAM was not available for
use by one or more Function Blocks.

Yes

Yes

Yes

Minor

Major

These Function Blocks require use of
DRAM: CAVE, LDelay, NDelay, and
REFQ. One of these FBs was unable to
allocate memory to support its function.
Recycle power to Smart Trac AC1. If
problem persists, replace Smart Trac
CPU card.