Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 53

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 52 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
52
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault
No
.
Fault Legend
Description
1757E
95614
30078
Not used
1757F
95615
30079
Not used
17580
95616
30080
Not used
17581
95617
30081
OPE1 Fault
kVA Selection. Smart Trac AC1
capacity selection. The inverter’s
model number has been changed
from factory setting or inverter card
has been replaced from original.
Yes
Yes
Yes
Minor
Major
Change inverter parameter o2-04,
Inverter Model #, to correct value.
17582
95618
30082
OPE2 Fault
Limit. Parameter set out of range.
Attempt is made to change an
inverter setting to a value outside
the permitted range.
Yes
Yes
Yes
Minor
Major
Do not attempt to change an inverter
parameter to a value outside the
permitted range. May need to do a 2-
wire reset to drive
17583
95619
30083
OPE3 Fault
Terminal. Multi-function input
setting fault.
Yes
Yes
Yes
Minor
Major
Applies to inverter parameters H1-01
through H1-06: two or more
parameters are set to the same data –
other than ‘F’, ‘FF’, or 20 to 2F hex.
17584
95620
30084
Not used
17585
95621
30085
Not used
17586
95622
30086
OPE6 Fault
PG Opt Missing. PG card not
installed.
Yes
Yes
Yes
Minor
Major
Control method set to flux vector or
V/F with PG, and no PG card is
installed. Ensure that A1-02= 1 or 3.
17587
95623
30087
Not used
17588
95624
30088
Not used
17589
95625
30089
Not used