Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 45

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 44 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
44
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault
No
.
Fault Legend
Description
17547
95559
30023
Overspeed
OS – Motor overspeed. Motor speed
exceeded overpspeed level set by
inverter parameters F1-08, F1-09.
Yes
Yes
Yes
Minor
Major
Check for correct tach (encoder) PPR
value in inverter parameter F1-01.
May have excessive noise on encoder
signal inputs to Smart Trac AC1
drive. Consult MagneTek about
specifications of user-supplied
encoder. Major fault declared only if
inverter parameter F1-03
≠
3, else a
minor fault.
17548
95560
30024
Speed Deviation
DEV – Speed deviation. Difference
between speed reference and speed
feedback exceeded the deviation
level set in inverter parameters F1-
10, F1-11.
Yes
Yes
Yes
Minor
Major
Decrease load, increase
acceleration/deceleration times, or
increase deviation levels found at
inverter parameters F1-10, F1-11.
The input labeled ‘Major’ will be set
only if inverter parameters A1-02 = 1
or 3, and d5-01 = 0, and F1-04
≠
3.
17549
95561
30025
PG Open
PGO – PG cable wires are
disconnected, bad tach, tach is not
connected to motor, or missing tach
power supply. This is actually a
tach loss condition.
Yes
Yes
Yes
Minor
Major
Connect wires from the Smart Trac
AC1 PG card to encoder, or look for
damaged wires. The input labeled
‘Major’ will be set only if inverter
parameters A1-02 = 1 or 3, and d5-01
= 0, and F1-02
≠
3.
1754A
95562
30026
Input Pha Loss
PF – Inverter input phase missing.
Incoming power supply has an open
phase, or a large imbalance exists
between L1, L2, and L3.
Yes
Yes
Yes
Minor
Major
Check input AC supply. Note:
inverter parameter L8-05 = 1 enables
this fault.