Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

1753F

95551

30015

DynBrk Resistor

RH – Dynamic braking resistor
overheat. Braking resistor unit
temperature exceeded allowable
value. (Heatsink-mount resistor
only, and only if inverter parameter
L8-01 = 1).

Yes

Yes

Yes

Minor

Major

Allow dynamic braking resistors to
cool before continuing operation. If
problem persists, decrease load sizes
or reevaluate dynamic braking
requirements.

17540

95552

30016

External Fault 3

EF3 – External fault signal at
terminal 3 of the inverter card. This
can be programmed to be N.O. or
N.C. contact.

Yes

Yes

Yes

Minor

Major

A fault has occurred in circuits
outside the Smart Trac AC1 inverter
card. Troubleshoot and correct. The
input labeled ‘Major’ will be true
only if inverter parameter H1-01 = 20
to 2B hex.

17541

95553

30017

External Fault 4

EF4 – External fault signal at
terminal 4 of the inverter card. This
can be programmed to be N.O. or
N.C. contact.

Yes

Yes

Yes

Minor

Major

A fault has occurred in circuits
outside the Smart Trac AC1 inverter
card. Troubleshoot and correct. The
input labeled ‘Major’ will be true
only if inverter parameter H1-02 = 20
to 2B hex.

17542

95554

30018

External Fault 5

EF5 – External fault signal at
terminal 5 of the inverter card. This
can be programmed to be N.O. or
N.C. contact.

Yes

Yes

Yes

Minor

Major

A fault has occurred in circuits
outside the Smart Trac AC1 inverter
card. Troubleshoot and correct. The
input labeled ‘Major’ will be true
only if inverter parameter H1-03 = 20
to 2B hex.