Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 23

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 22 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
22
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault #
Fault Legend
Description
12AFB
76539
11003
Illegal Input
The input to a block has an
inappropriate input. The blocks
declaring this are CAVE, DAVE,
LDelay, NDelay, REFQ, TENR_1,
POSR_1, and POSR_2. These
function blocks expect parameter
inputs within a specified number
range.
( Note: this fault applies to
MAG_CPB libraries V1.8 and
older. )
Yes
Yes
Yes
Minor
FB_se
tup
Refer to block description Help in Smart
Trac AC1 Workstation software. Obey
these limits:
Samples for CAVE = 1 to 500;
Samples for DAVE = 1 to 1000;
Delays for LDelay = 1 to 500;
Delays for NDelay = 1 to 500;
REFQ CascadeNumber = 1 to
MaxCascadeNumber;
TENR_1 needs inputs for Webwidth,
WebThickness and TensionZoneLength.
POSR_1 Roll_Diameter > 1;
For POSR_2, all of these must be > 0:
RatedLineSpd, R1_Factor, R2_Factor,
RatedDancerStorage,
S_RPM_At_M_RPM,
POSR_0_ScanTime.
12AFC
76540
11004
PG Illegal
Port
The port setting to the
PG_ANALOG_IN, PG_DELTA_P,
or PG_TACH block is not one of the
legal values of 0, 1, 2 or 3.
Yes
Yes
Yes
Minor
Major
Port number is used to identify the PG
card. Note: older versions of the PG card
had legal values of 0 through 3. Newer
PG cards have only one port setting. Use
PortNumber = 1.
12AFD
76541
11005
PG Illegal
Chan
The channel input setting to the
PG_TACH or PG_ANALOG_IN
block is not one of the legal values
of 0 or 1.
Yes
Yes
Yes
Minor
Major
Use only channel 0 or channel 1. All
other values will cause this fault.
Reference drive schematic to set
correctly.