29
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault #
Fault Legend
Description
12B66
76646
11110
GEAR Input
A GEAR function block has detected
a value of ‘0’ for its
“InputGear_Denominator” input.
No
Yes
Yes
Minor
FB_se
tup
Ensure that the GEAR function block
input(s) “InputGear_Denominator” is not
set to zero.
12B67
76647
11111
POSR_0
Input
A POSR_0 function block has
calculated an out of range value for
its “DancerOut” output.
“DancerOut” is the “DancerSignal”
modified by a SPAN and ZERO
adjustments provided by
corresponding the POSR_1 function
block. “DancerOut” is a per-unit
number and this fault is declared if
“DancerOut” calculates as less than
-0.1 or greater than +1.1.
No
Yes
Yes
Minor
FB_se
tup
Ensure that the DancerSignal of the
corresponding POSR_1 function block
has been calibrated. Ensure that the
dancer feedback mechanism has not
moved. The dancer signal in the
corresponding POSR_1 function block
may need recalibration.