Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
32
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault #
Fault Legend
Description
14E28
85544
20008
DPRAM Write@
UV
Dual Port RAM write
requested between the Smart
Trac AC1 CPU card and the
inverter control card while
there is an undervoltage fault
No
Yes
Yes
Minor
Minor
Correct undervoltage issue – check quality
of AC power supply.
14E29
85545
20009
DPRAM
Write@Calc
Dual Port RAM write
requested between the Smart
Trac AC1 CPU card and the
inverter control card, while a
parameter is being calculated.
No
Yes
Yes
Minor
Minor
The inverter card continually performs
background calculations on internal
parameters. If this fault persists, consult
the factory.
14E2A
85546
20010
DPRAM Unknwn
Rsp
Unknown Dual Port RAM
response between the Smart
Trac AC1 CPU card and the
inverter control card.
Yes
Yes
Yes
Minor
Major
Smart Trac AC1 CPU card received
information from inverter card that is
incorrect. Inverter firmware may be wrong
version or inverter card may be defective.
14E2B
85547
20011
DPRAM Tref
Hndsk
Dual Port RAM 2ms Torque
Reference handshake fault
between the Smart Trac AC1
CPU card and the inverter
control card.
Yes
Yes
Yes
Minor
Major
and
Minor
Check integrity of physical connection
between Smart Trac AC1 CPU card and
inverter card. Check Inverter Type in Boot
menu: for most cases, value should be set
for 2 ms Torq Update. Application
program may be overburdened – reduce
amount of logic placed in fast Tasks (15ms
or faster) to slow Tasks (30ms or slower).