Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 49

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 48 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
48
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault
No
.
Fault Legend
Description
04- Internal A/D Err. Internal A/D
fault.
05- External A/D Err. External A/D
fault.
06- Option Error. Option card
connection failure.
21- Option CPU down. Smart Trac
AC1 self-diagnostic error.
22- Option Type Err. Smart Trac
AC1 Model code error.
23- Option DPRAM Err. Smart
Trac AC1 DPRAM error. Dual
Port RAM handshake between
Smart Trac AC1 CPU card and
inverter card has been lost.
be programmed incorrectly.
Check for valid Boot, Monitor,
and Kernel firmware.
22- Smart Trac AC1 CPU card may
be programmed incorrectly.
Check for valid Boot, Monitor,
and Kernel firmware. Check
Inverter Type in Boot menu: for
most cases, value should be set
for 2 ms Torq Update.
23- Check physical connection of
both Smart Trac AC1 CPU card
and PG card. Application
program may be bad or
extremely overburdened.
17560
95584
30048
OPExx Param Err
OPE – Operation Error. A general
error condition that refers to one of
several problems:
01- kVA Selection. Smart Trac
AC1 capacity selection. The
inverter’s model number has
been changed from factory
setting or inverter card has been
replaced from original.
02- Limit. Parameter set out of
range. Attempt is made to
change an inverter setting to a
Yes
Yes
Yes
Minor
Major
01- Change inverter parameter o2-
04, Inverter Model #, to correct
value.
02- Do not attempt to change an
inverter parameter to a value
outside the permitted range.
03- Applies to inverter parameters
H1-01 through H1-06: two or
more parameters are set to the
same data – other than ‘F’, ‘FF’,
or 20 to 2F hex.
05- Frequency reference and/or Run