Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 35

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 34 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
34
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault #
Fault Legend
Description
14EEF
85743
20207
LAN Rem Out
Time
Remote No Output
Command Fault – This
message is sent from a
remote I/O node when
it does not receive an
output command LAN
message from a Smart
Trac AC1 drive, that
has allocated one or
more outputs, within
the prescribed time.
No
Yes
Yes
Minor
Minor
Possibility that a supporting Task in Smart
Trac AC1 has encountered a fault.
14EF0
85744
20208
LAN Rem Num
In
Numeric Input
Request Fault – This
message is sent from
the remote I/O node to
the Smart Trac AC1
drive when the remote
I/O node cannot
provide a digital
numeric input to the
drive for reasons other
than LAN failure.
No
Yes
Yes
Minor
Minor
A typical reason for this condition might be
that there is no digital numeric input module
located at the given channel/subchannel.