Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual
Page 46

10/17/00
New Berlin
Technology Center
Smart Trac
Product
Development
Design
Document
Faults.doc
Rev. # 19
Page 45 of 64
Title: Fault Declarations
The information contained in this document is the
CONFIDENTIAL
property of
MagneTek Inc.
File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC
Print Date: 10/17/00
45
Displayed Fault
No.
Priority
D
is
p
lay?
Newest
List
?
Ol
d
es
t
List
?
Severity
Assig
n
Program
Input
Corrective Action
Control
Node
Monitor
Fault
Manager
In
ternal Fault
No
.
Fault Legend
Description
1754B
95563
30027
Output Pha Loss
LF – Drive output has open phase.
Yes
Yes
Yes
Minor
Major
Check wiring between inverter and
motor. Note: inverter parameter L8-
07 = 1 enables this fault.
1754C
95564
30028
Not used
1754D
95565
30029
Oper Disconnect
OPR – Operator disconnected.
Digital operator has been
disconnected from drive while in
Run mode.
Yes
Yes
Yes
Minor
Major
Reconnect digital operator to inverter
or disable this fault by setting
inverter parameter o2-06 = 0.
1754E
95566
30030
EPROM R/W Err
ERR – EPROM write-in fault.
Attempt to write to nonvolatile
memory has failed.
Yes
Yes
Yes
Minor
Major
Cycle power and then attempt to
initialize. If fault persists, Smart Trac
AC1 inverter card is bad.
1754F
95567
30031
Not used
17550
95568
30032
Memobus Com Err
CE – Communication fault. Control
data was not received for 2 seconds
after initial communication.
Yes
Yes
Yes
Minor
Major
Check validity of Smart Trac AC1
CPU card firmware and application
program. This fault is declared only
if H5-04= 0, 1 or 2 and H5-05= 1.
17551
95569
30033
Option Com Err
BUS – Communication fault.
Communication fault while drive is
set for Run Command and/or
Frequency Reference from Smart
Trac AC1 CPU card.
Yes
Yes
Yes
Minor
Major
Check validity of Smart Trac AC1
CPU card firmware and application
program. Ensure inverter parameters
B1-01, B1-02 = 3. Note: The input
labeled ‘Major’ is set only if inverter
parameter F9-06
≠
3.