2 troubleshooting, Alarm codes, Cent’d) (parity error) – Yaskawa i80M Maintenance Manual User Manual
Page 90

4.2 TROUBLESHOOTING
4.2.2 ALARMS 0010 AND 0011
Cause of Trouble
Alarm 0010
(TH Error)
Alarm 0011
(TV Error)
BY
ALARM CODES
(Cent’d)
(PARITY ERROR)
Table 4.2
Check Method
) In case of tape operation:
number of data holes for each character
s checked on the NC tape.
alarm is issued when the number is:
Even: For EIA tape
Odd: For 1S0 tape
(The description that follows applies to the
EIA code. )
8 0
7 0
5 0
4 0
●
3 0
2 0
1 0
LSK
456C
RR
BLOCK DATA
128 CHARACTERS OR LESS
EOR
In case of memory operation or at time of
EDIT, failure in program area.
In case of tape operation:
The tape should be capable of TV check.
(Number of characters for one block should
be even, including EOB. )
Solution
Clean tape reader.
Check tape itself if the
feed hole is faulty and/or the
nap is raised on the hole.
Failure of tape reader itself
Failure of JANCD-FC200 board
or of expansion memory
board
board)
If the tape cannot perform TV
check, use it by setting
= O,
=
O (TV check OFF) or make it so
that it can perform TV check.
82
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)