4.3.15 TAPE MODE DOES NOT FUNCTION

Cause of Trouble

Failure of
input signal.
Mode input
is not correct.

TAPE mode
does not start,

Parameter
failures such
as baud rate,
stop bit, and
control code

Tape reader
setting failure

Connection
failure

Failure of

reader

Other

Failure of tape
reader power

(EYG 300/55

Table 4.44

T a p e

M o d e D o e s N o t F u n c t i o n

Check Method

/0

signal

should be 1 and

Do to D3 and D5 to D7 should

e O. (TAPE should appear on CRT screen. )

In i80L multi-program system,

for second program and

for

bird

Par. 4.3.8, “CYCLE START FAILURE”.

Par. 4.2.3, “ALARMS 0016, 0017, 0018, 9016, 9017 AND 9018

RS-232C ERROR) “ .

Switch

For

Input

For

For PTR

Control Self-

Speed

tion

ing

B1

B2

OFF

OFF OFF

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

OFF OFF

OFF

ON

ON

OFF

Standard setting

Read

Spaed

char/s

270

300

200

Trans-

mission

AUTO

Self-

Input

Beud

Checking

5600

AUTO

2400

AUTO

1200

AUTO

checking

Code

control

Line

control

( D

IP

switch arrangement) . standard setting

Setting of Tape Reader

Check the wiring status of RS-232C cable according to the YASNAC
i80 Connecting Manual (TOE -C843-11.5).
Check loosening and removal of connector.

Depressing the switch for feeding tape does not cause the tape to be
moved .“
LED

of the

reader is off.

1. Power to the

reader is off.

2. The tape reader itself is defective.

Check the tape retainer again.

Check that input voltage 200 V is supplied.

Check that output voltage is 5 V or 24 V.

Solution

Check set-
ting status
of tape read-
er Model
2801 B-2
according to
the table on
the left and
set it cor-
rectly again.

Correct
connection.
Plug in the
connector
again.

Replace the
tape reader.

model

board

or failed cable

tape reader.