Troubleshooting without alarm codes (cent’d) – Yaskawa i80M Maintenance Manual User Manual
Page 126

4.3
TROUBLESHOOTING WITHOUT ALARM CODES (cent’d)
Table 4.35
Manual Rapid Mode Operation Faulty (Cent’d)
Cause
Trouble
Rapid
override
not
Param-
eters no
set
An axis
signal
entered,
The ma
chine is
in
position
Check Method
For 6 steps specifications
Input Status
R a p i d T r a v e r s e R a t a
R O V 4 R O V 2 R O V 1
to 8th-axis
1
0
1
(pm2449 Setting speed)
Setting speed)
100%
50%
o
0
25%
o
0
0
F
O
(pm2447 Setting speed)
the following 1/0 signals:
pm2801 lst-axis rapid traverse rate
pm2805 5th-axis rapid traverse rate
pm2802 2nd-axia rapid travers rate
pm2806 6th-axis rapid traverse rate
pm2803 3rd-axis rapid traverse rate pm2807 7th-axis rapid traverse rate
pm2804 4th-axis rapid traverse rate
pm2808 8th-axis rapid traverse rate
Jog is correct when:
#3078 D
o 1 (
#3078
= 1 (5th-axis)
#3078 D = 1 (2nd-axis)
#3078
= (6th-axis)
#3078
= 1 (3rd-axis)
#3078
= 1 (7th-axis)
#3078 D, = (4th-axis)
#3078
= 1 (8th-axis)
When O, the axis does not work.
[/0 signal #3006 D = 1. (In i80L multi-program system, pm3056, for second
program and #3066 D
6
for third program. )
Setting pmOOOO D = 1 (In i80L multi-program system, pmO024 D = for second
program and pmO027 D, = 1 for third program. )
Check machine lock switch input.
Solution
set
An axis
interlock
is
some
reason.
Refer to
the manu-
al of the
machine
manufac-
turer to
release
the axis
interlock.
Check
switch.
Check
whether
parameter
118