beautypg.com

Yaskawa i80M Maintenance Manual User Manual

Page 116

background image

4.3

TROUBLESHOOTING WITHOUT ALARM CODES (Cent’d)

( 3 ) Operation Monitoring

S o f t w a r e

Normal operation of the
b y s o f t w a r e .

System software checks

entire system is monitored

whether a partner CPU is

normally operating among CPUs.

If the partner CPU

is stopped, an alarm occurs.

Numbers checked . . .

ALM3260 :

SMON-INTEX

Synchronous error

:

SMON-MMON Synchronous error/
Synchronous error (

ALM3262 :

Synchronous error

ALM3263 :

MMON-PLC Synchronous error

Synchronous error ( i80B )

ALM3264 :

Synchronous error/MOTION-AXIS

Synchronous error (

ALM3265:

Synchronous error

ALM3266 :

DNC Synchronous error

( 4 )

( 5 )

Operation Monitoring by Hardware

Normal operation of system software is monitored by
h a r d w a r e .

This is performed for specific system

numbers.

When system software does not access hardware for a

given period, it is regarded as a hardware failure
and a hardware monitoring error is displayed.

checked . . . “O”, “ , “2”,

D i v i s i o n E r r o r

A division error occurring in system software is
d e t e c t e d a n d t h e e n t i r e s y s t e m i s s t o p p e d . T h e
address in which the division error occurred is

displayed on the screen.

108