4.2.24 ALARMS 3331 TO 3335 (OVERVOLTAGE)

Table 4.26

Alarms 3331 to 3335 (Overvoltage)

Causeof Trouble

Check Method

I

Solution

Excess load

Regenerative
processing circuit
error

Alarm occurs when motor is started or slowed
down.

Alarm occurs when motor is started or slowed
down.

Check load machine
inertia converted
into motor axis.

Replace

4.2.25

ALARMS 3341 TO 3345 (UNDERVOLTAGE)

Table 4.27

Alarms 3341 to 3345 (Undervoltage)

Cause of Trouble

Check Method

Solution

Main circuit

Alarm occurs after main circuit power is turned Replace

th yristor-diode

ON.

SERVOPACK.

module error

4.2.26 ALARMS 3351 TO 3355 (HEAT SINK OVERHEAT)

Table 4.28

Alarms 3351 to 3355 (Heat Sink Overheat)

Cause of Trouble

Control board fault

Fan stops

High ambient
temperature near

(over 55°C

Motor circuit
connection error

Check Method

Alarm occurs immediately after control power

turned ON.

Alarm occurs during operation. (If control
power is turned OFF and then immediately

turned ON again, alarm remains ON. Operation
can be restarted only if system is reset after a
while. )

Alarm occurs during operation. (If control
power is turned OFF and then immediately

ON again, alarm remains ON.

Operation can be restarted only if system is

reset after a while. )

Motor turns at low torque. Alarm occurs
after a while.

S o l u t i o n

whether fan

s running.

Take necessary
action to lower
servopack ambient
temperature.

Connect properly.

101