Adjustments upon installation, Cent’d ) – Yaskawa i80M Maintenance Manual User Manual
Page 146

5.
ADJUSTMENTS UPON INSTALLATION
(Cent’d )
( 4 )
( 5 )
( 6 )
( 7 )
Connect the Power Input
C a b l e .
Before connecting the
power input cable, verify
that power input terminals
R, S, and T inside the unit
are not shorted.
Check Connector and Module
Locations and Insertions.
●
Check that
the module
ghtened on
Check that
the screws on
clamps are ti-
the CPU rack.
the clamp
claws on Honda connectors
are tightened and that
clamp screws are securely
in place.
●
Check that the clamp
claws on power supply
connectors are in place.
●
Check that the clamp
claws on flat cables are
in place.
C h e c k S e t t i n g .
Verify the control power
transformer setting in refer-
ence to the input power
supply voltage.
Check Input Power Supply
V o l t a g e a n d F r e q u e n c y .
●
Check that the power
Don’t cause
short.
-
o
Power
input
S termi nal
T
SCREWDRIVER
supply voltage and
Input power
quency meet ratings.
Check that the input
supply,
0 0
voltage,
power supply capacity is
frequency
high enough for power
consumption of the
control unit,
138
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)