4.3 TROUBLESHOOTING WITHOUT ALARM CODES (Cent’d)

4.3.2 SOLUTION TO ERRORS DETECTED IN SELF-DIAGNOSIS

Table 4.32

to Errors Detected

Cause of Trouble

Check Method

Error identified by
self-diagnosis

Both diagnostic items passed and the
diagnostic item leading up to the error
are displayed and the NC unit stops.
CPU cannot function normally and this is
a major failure. The main system shuts
off the servo power, but, depress the emer-

gency stop and power OFF buttons to
check for proper AC input voltage and
ensure power is OFF.

Solution

Record the diagnostic
item leading up to NC
unit stop, turn on power

again and contact your
YASKAWA representative.
Remove any noise source
near the NC unit. Turn
on the main power under
emergency stop conditions.
Contact your YASKAWA
representative immediate-
ly if it is “CPU ERROR”.

If normal, start operation
after ensuring correct
parameters, settings,

offsets and programs.

4.3.2.1 SELF-DIAGNOSIS FUNCTIONS

Self-diagnosis functions are:

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

Memory Check

CMOS check

ROM check

RAM check

System Consistency Check

Operation

g by Software

Operation Monitoring by Hardware

Division Error Detection

LED Display

Processing Program Area, Initialization

Expanded Memory Consistency Check

Axis Configuration Parameter Consistency Check

(10) Overheat Detection

(11 ) Battery Alarm Detection

104