Model JANCD-FC400

Swl :

System number switch (16-position rotary switch)

[11:

[ 2 ] :

[41:

Normal operation mode

When power is applied, the system is
started up in synchronization with NC
and an application program (index )

is executed immediately.

NC

built-in program development mode

When power is applied, the system is

started up in synchronization with NC

and the screen of application program
development mode is displayed.

Stand-alone

execution

mode

When power is applied,

is

started up singly and an application

program (index “ ) is executed
immediately.

Stand-alone

program development mode

When power is applied, ACGC is

started up singly and the screen of

application program development mode
is displayed.

SW [3], and [5] to [F] are

used only for maintenance.

Only YASKAWA service personnel
must use these switches.